4RF Limited SRN0400025A ユーザーズマニュアル

ページ / 233
34  |  Product Options 
 
 
Aprisa SR User Manual 
 
Spares 
The Aprisa SR Protection Switch is available as a spare part. This spare includes the protection switch and 
two sets of Protection Switch interconnect cables (one set is 6 cables).  
 
Part Number 
Part Description 
APSP-SRPSW 
4RF Spare, Aprisa SR, Protection Switch 
 
The set of interconnect cables is available as a spare part (set of 6 cables). 
 
Part Number 
Part Description 
APSP-SRPSC-ST6 
4RF Spare, Aprisa SR, Protection Switch Cables, Set Of 6 
 
Replacing a Faulty Protection Switch 
Note: Replacing a faulty Protection Switch will disrupt traffic. 
Move the radios, the interconnect cables, the interface cables and the power cables to the replacement 
Protection Switch. 
 
On both Protected Station radios: 
1.  Power on the radio and wait for it to become ready. 
2.  Using  SuperVisor  >  Maintenance  >  Advanced,  enter  the  RF  Interface  MAC  address  shown  on  the 
Protection Switch label (see ‘RF Interface MAC address’ on page 133). 
3.  Using  SuperVisor  >  Maintenance  >  Advanced,  Decommission  the  node  (see  ‘Decommission  Node’  on 
page 133) and then Discover the Nodes (see ‘Discover Nodes’ on page 133).  
 
Ensure that the Hardware Manual Lock switch is set to the Auto position. 
The Aprisa SR Protected Station is now ready to operate.