36  |  Product Options 
 
 
Aprisa SR User Manual 
 
Switch Over 
The active radio is determined explicitly by which radio receives data on its RS-232 serial port. 
The switching and blocking criteria used for the standard Protected Station do not apply. This means that 
events and alarms on the unit are not used as switching criteria. 
 
Configuration Management  
The  Primary  and  Secondary  radios  are  managed  with  the  embedded  web-based  management  tool, 
SuperVisor  (see  ‘Managing  the  Radio’  on  page  59)  by  using  either  the  Primary or  Secondary  IP  address. 
Configuration changes in one of the radios will automatically be reflected in the partner radio. 
Changes to the Network Table are automatically synchronized from the active radio to the standby radio 