50  |  Preparation 
 
 
Aprisa SR User Manual 
 
Site Requirements 
Power Supply 
 
Ensure a suitable power supply is available for powering the radio. 
The nominal input voltage for a radio is +13.8 VDC  (negative earth) with an input voltage range of +10 to 
+30 VDC. The maximum power input is 30 W. 
 
 
WARNING: 
Before connecting power to the radio, ensure that the radio is grounded via the 
negative terminal of the DC power connection. 
 
Equipment Cooling 
 
If the Aprisa SR is operated in an environment where the ambient temperature exceeds 50°C, the Aprisa 
SR convection air flow over the heat sinks must be considered. 
 
The environmental operating conditions are as follows: 
 
Operating temperature 
-40 to +70˚ C 
Storage temperature 
-40 to +80˚ C 
Humidity 
Maximum 95% non-condensing 
 
 
 
WARNING: 
If  the  Aprisa  SR  is  operated  in  an  environment  where  the  ambient  temperature 
exceeds 50°C, the Aprisa SR must be installed within a restricted access location to 
prevent human contact with the enclosure heatsink.