Earthing and Lightning Protection 
 
 
WARNING
Lightning can easily damage electronic equipment. 
To avoid this risk, install primary lightning protection devices on any interfaces that 
are reticulated in the local cable network. 
You should also install a coaxial surge suppressor on the radio antenna port. 
 
Feeder Earthing 
Earth  the  antenna  tower,  feeders  and  lightning  protection  devices  in  accordance  with  the  appropriate 
local and national standards. The diagram below shows the minimum requirements. 
Use grounding kits as specified or supplied by the coaxial cable manufacturer to properly ground or bond 
the cable outer. 
 
 
 
Radio Earthing 
The Aprisa SR has an earth connection point on the top left of the enclosure. A M4 8mm pan pozi machine 
screw and a M4 lock washer is supplied fitted to the radio. This can be used to earth the enclosure to a 
protection earth.