4RF Limited SRN0400025A ユーザーズマニュアル

ページ / 233
 
Installing the Radio  |  55 
 
Aprisa SR User Manual 
 
Installing the Antenna and Feeder Cable 
 
Carefully  mount  the  antenna  following  the  antenna manufacturers’  instructions.  Run  feeder  cable  from 
the antenna to the radio location. 
Lightning  protection  must  be  incorporated  into  the  antenna  system  (see  ‘Earthing  and  Lightning 
Protection’
 on page 51)
 
 
WARNING: 
When the link is operating, there is RF energy radiated from the antenna. 
Do not stand in front of the antenna while the radio is operating (see the ‘RF 
Exposure Warning’ on page 3). 
 
Fit the appropriate male or female connector (usually N-type) to the antenna feeder at the antenna end. 
Carefully follow the connector manufacturers’ instructions. 
Securely attach the feeder cable to the mast and cable trays using cable ties or cable hangers. Follow the 
cable manufacturer’s recommendations about the use of feeder clips, and their recommended spacing. 
Connect the antenna and feeder cable. Weatherproof the connection with a boot, tape or other approved 
method. 
The Aprisa SR antenna connection is a TNC female connector so the feeder / jumper must be fitted with a 
TNC male connector. 
If  a  jumper  is  used  between  the  feeder  and  the  radio,  connect  a  coaxial  surge  suppressor  or  similar 
lightning  protector  between the  feeder  and  jumper  cables  (or  at  the  point  where the  cable  enters  the 
equipment shelter). Connect the feeder cable to the antenna port on the radio. 
Earth the case of the lightning protector to the site Lightning Protection Earth. 
The Aprisa SR has an earth connection point on the top left of the enclosure. A M4 8mm pan pozi machine 
screw and a M4 lock washer is supplied fitted to the radio. This can be used to earth the enclosure to a 
protection earth.