MG International 040 ユーザーズマニュアル

ページ / 25
Installation and operation guide - 6 
 
Failure signals 
 
Sound signals 
Failure 
With the magnet 
Periodic 
Batteries low 
4 short, low-pitched 
beeps 
1 short, low-pitched beep every minute 
Malfunction 
Return to the after-sales 
service 
–  
2 short, low-pitched beeps every 
minute 
 
5  Installing Swim Alert™  
 
INSTALLATION PRECAUTIONS 
 
Check that the Swim Alert
TM 
 sirens can be heard from inside your home. 
 
Your fall detector must be installed in good weather on a still pool. 
 
The alarm system must be installed at a location where the water depth is 12 in. minimum. 
 
The probe (rigid angled tube + black flexible tube) might have to be cut to obtain an immersion depth 
of  8.5  in.  (+/-  1  in.).  The  installation  of  a  level  controller  is  recommended.    Contact  your  retailer  for 
advice. 
 
Make sure that the water in your pool is clear and pure before installing your device. 
 
Some robot cleaners of the diving robot type are incompatible with fall detection systems. 
 
Proper operation of Swim Alert
TM
 cannot be guaranteed in the presence of a bubble pool cover. 
 
Warning: Swim Alert™ is fitted with a powerful siren (over 100 dB). In case the siren should go off, 
please take all necessary precautions to protect your auditory system during the installation. 
 
Tools required for installation: 
 
 
 
1 Phillips screwdriver 
 
1 tape measure 
 
1 2.5 US gallon jerry can 
 
1 rope about 6 ft long. 
 
1 drill with concrete bit Ø 0.31 in (8mm)  
 
1 hacksaw 
 
1 pencil 
 
Your fall detector is installed in 6 steps: 
 
5.1 Insertion of the batteries 
5.2 Choice of location 
5.3 Temporary installation 
5.4 Installation tests 
5.5 Final installation 
5.6 Validation tests 
 
U
TMOST VIGILANCE IS REQUIRED FROM THE PARENT
/
RESPONSIBLE ADULT DURING THE INSTALLATION OF 
YOUR FALL DETECTOR