MG International 040 ユーザーズマニュアル
Installation and operation guide - 9
5.3 Installation for testing
-
Place the 3 pieces of stabilizing foam under the device (Pict. 6)
-
Position the device at the selected location, making sure that the distance between the probe and the
edge of the coping is at least 0.2 in (Pict. 7).
edge of the coping is at least 0.2 in (Pict. 7).
-
Check the immersion depth. If your probe is immersed by more than 8.5 in. (+/-1 in.) (see §5.2), cut it
carefully using a hacksaw (both the tube and the flexible tube at the same time) to obtain a proper
immersion depth (Pict 8). If the water level has been deliberately lowered, suitable probe extenders are
available from your retailer.
carefully using a hacksaw (both the tube and the flexible tube at the same time) to obtain a proper
immersion depth (Pict 8). If the water level has been deliberately lowered, suitable probe extenders are
available from your retailer.
-
Your device is in OFF mode, and should be activated for the installation tests by moving the magnet
over the swimmer symbol area.
over the swimmer symbol area.
-
You will hear 5 short beeps, the red indicator light flashes, you are in DISARMED mode.
-
Wait for the automatic switch to ARMED mode (1 long beep, green indicator light flashing) before
starting the tests.
starting the tests.
Pict 6
Pict. 7
Pict 8
8.5 in (+/- 1 in)
0,2 in mini