Installation and operation guide - 9 
5.3  Installation for testing 
 
-
 
Place the 3 pieces of stabilizing foam under the device (Pict. 6)  
-
 
Position  the  device  at  the  selected  location,  making  sure  that  the  distance  between  the  probe  and  the 
edge of the coping is at least 0.2 in (Pict. 7). 
-
 
Check the immersion depth. If your probe is immersed by more than 8.5 in. (+/-1 in.) (see §5.2), cut it 
carefully  using  a  hacksaw  (both  the  tube  and  the  flexible  tube  at  the  same  time)  to  obtain  a  proper 
immersion depth (Pict 8). If the water level has been deliberately lowered, suitable probe extenders are 
available from your retailer. 
-
 
Your  device  is  in  OFF mode,  and  should  be  activated  for  the  installation  tests  by  moving  the  magnet 
over the swimmer symbol area. 
-
 
You will hear 5 short beeps, the red indicator light flashes, you are in DISARMED mode. 
-
 
Wait  for  the  automatic  switch  to  ARMED mode  (1  long  beep,  green  indicator  light  flashing)  before 
starting the tests. 
 
 
 
  
 
 
 
 
 
 
 
 
Pict 6 
Pict. 7 
Pict 8 
8.5 in (+/- 1 in) 
0,2 in mini