5.4  Tests  
-
 
Make sure that the pool is still. If you have a swim jet, turn it off. 
-
 
Prepare a 2.5 US gallon jerry can  with enough  water to reach a  weight of 18 lbs (8 kg), and tie the 6 
foot rope to it to recover it when performing fall tests. 
 
NOTE:  If  you  wish,  you  can  conduct  your  tests  in  low-volume  siren  mode  (optional).  In  this  mode,  the 
volume  of  the  siren  is  reduced  and  the  siren  stops  automatically  after  5  seconds.  Refer  to  §
7.5
  for  further 
details
-
 
For these tests, Swim Alert™  must be in ARMED mode (green indicator light flashing). If such is not 
the case, move the magnet over the swimmer symbol. 
-
 
If  in  spite  of  this,  the  indicator  light  does  not  switch  to  green,  this  means  that  the  pool  is  not  still 
enough. You must imperatively wait until your pool is still before carrying out the tests. 
 
 
Test 1 - Robot cleaner + filtering 
-
 
Leave Swim Alert™  in ARMED mode for 10 minutes with the filtering on and the robot cleaner working, 
only if you have a robot cleaner. 
o
 
Swim  Alert™    must  remain  in  ARMED mode  (green  indicator  light  flashing)  without  the  siren 
going off. 
 
Some diving type robot cleaners (a robot which moves out of and dives back into the water, possibly causing a 
disturbance similar to a fall) are not compatible with fall detectors. 
If this test fails: 
Look up item 8, page X. 
Contact your retailer 
Contact our technical support service: usa@swim-alert.com 
 
 
Test 2 - Falls 
-
 
Make  sure  that  your  device  is  in  ARMED mode 
(green indicator light flashing) 
 
1)  Move  to  the  spot  furthest  away  from  your  fall 
indicator (Pict. 9) 
-
 
Simulate  the  fall  of  a  person  by  dropping  the  18 
lbs jerry can from the top of the coping. 
o
 
The  siren  must  go  off  less  than  20  seconds 
after the fall.  
o
 
Turn the alarm off by moving the magnet over 
the swimmer symbol. 
Wait for your fall detector to restart automatically (1 
long beep – green indicator light flashing). 
 
 
During  the  tests,  after  each  fall,  you  must  wait  for  the  automatic  reactivation  of  Swim  Alert™  before 
performing another fall. Depending on wind and pool disturbance conditions, this reactivation may take 
about ten minutes.
 
 
2) Move to 3 feet away from your fall detector 
-
 
Simulate the fall of a person by dropping the 18 lbs jerry can from the top of the coping.  
o
 
The siren must go off less than 20 seconds after the fall.  
o
 
Turn the alarm off by moving the magnet over the swimmer symbol.  
The test is validated. 
 
If one of these tests fails: 
Look up § 8. 
Contact your retailer 
Contact our technical support service: usa@swim-alert.com  
 
All the tests have been conducted successfully, you may now proceed with the final installation of your device. 
Pict. 9