1.3. 
SITE REQUIREMENTS 
Usually the Cabinets will be fixed to existing walls in the positions determined by the Site 
Survey. 
 
Do not mount the AP300 to a metal wall! 
 
 
1.4. 
TEMPERATURE RANGES 
The temperature range of the AP300 is: 
 
-  0
°
 to 45
°
 C. 
 
The outside temperature range for the AP300 (all types) mounted in the Outdoor Cabinet is 
as follows: 
 
Minimum outside temperature: -20
°
 C 
Maximum outside temperature: 45
°
 C  
 
 
1.5. 
CABLE SPECIFICATIONS FOR AP300 Types 
The cabling to the AP300(E) is “Category 5” Ethernet cabling.  The interface is defined as 
an SELV interface according EN60950-1.  For this reason the following safety restriction is 
applicable: 
 
Caution: 
The cabling and/or the AP300(E) may never be exposed to over-voltages (e.g. 
lightning).  Therefore,  the  AP300(E)  and  cabling  associated  with  it  may  never 
be installed outdoors! However there is an exception: if installed in the Outdoor 
Cabinet, and  the  Outdoor  Cabinet is mounted against a wall and the cable is 
led  directly  indoors,  it  is  permitted.  For  details  about  this  specific  installation 
refer to the installation manual of the Outdoor Cabinet. 
 
 
The power for the AP300(E) must be supplied via the Ethernet cable, PoE  (IEEE 802.3af). 
There is no room for a Mains Power adaptor inside the Outdoor Cabinet. 
 
 
1.6. 
G.729 DAUGHTER BOARD 
The AP300 does support the G.729 codec, but only if the G.729 Daughter Board is 