Baumer Electric AG OIS-W-WR300303 ユーザーズマニュアル
Baumer Ident AG
24 / 25
Author: Clemens Zehnder
File: Maintenance-SW.doc Version 3.0 e
4.1.6 Page 6: Interface Settings
Picture 4-7: interface settings
Term
Description
Range
Default Remarks
Bdrate ID Data
Baud rate serial interface RS 422 (R38)
12..1152
1152
9600 baud or 115200 baud
Bdrate Service
Baud rate serial interface RS 232 (R13)
12..1152
1152
9600 baud or 115200 baud
Msg Type ID
Select type of notification after successful reading
0..19
11
1
st
digit:
•
0: RS422
•
1: RS232
2
nd
digit
•
0: OFF
•
1: TAG_ID_IND
•
2: PARAM_DATA
TidF
Time constant ID filter (res:.5s)
0.5..32768
1
ID Msg Retry
Max. number transmissions of ID Msg (0 = forever)
0..255
3
ID Msg Timeout
Time until ID msg is retransmitted (res:0.5s)
0.5..127.5
1
Table 4-7: interface settings
Bdrate RS422 / ID Data
This parameter defines the baud rate of the serial interface RS 422 (R38).
Bdrate RS232 / Service
This parameter defines the baud rate of the serial interface RS 232 (R13).