4.1.6  Page 6: Interface Settings 
 
Picture 4-7: interface settings 
Term 
Description 
Range 
Default  Remarks 
Bdrate ID Data 
Baud rate serial interface RS 422 (R38) 
12..1152 
1152 
9600 baud or 115200 baud 
Bdrate Service 
Baud rate serial interface RS 232 (R13) 
12..1152 
1152 
9600 baud or 115200 baud 
Msg Type ID 
Select type of notification after successful reading 
0..19 
11 
1
st
 digit: 
• 
0: RS422 
• 
1: RS232 
2
nd
 digit  
• 
0: OFF 
• 
1: TAG_ID_IND 
• 
2: PARAM_DATA 
TidF 
Time constant ID filter (res:.5s) 
0.5..32768 
 
ID Msg Retry 
Max. number transmissions of ID Msg (0 = forever) 
0..255 
 
ID Msg Timeout 
Time until ID msg is retransmitted (res:0.5s) 
0.5..127.5 
 
Table 4-7: interface settings 
Bdrate RS422 / ID Data 
This parameter defines the baud rate of the serial interface RS 422 (R38). 
Bdrate RS232 / Service 
This parameter defines the baud rate of the serial interface RS 232 (R13).