•  Module Type (read-only) 
This property indicates the module type (Microflex or other) for the selected unit: 
•  Master ID (read-only) 
The module identification number of the unit’s master is displayed here. 
•  Master Port (read-only) 
The way the unit is connected to its master is provided with this property as 
follows: 
1) Drop & Insert: the unit is connected to the drop-and-insert (cabled) port 
of its master 
2) RF #x: the unit is connected to the RF port number x of its master. 
•  Firmware Version (read-only) 
This label contains a string indicating the firmware version downloaded in the 
selected unit. 
•  Radio Firmware Version (read-only) 
This label contains a string indicating the Radio firmware version downloaded in 
the selected unit. 
•  Video Firmware Version (read-only)  
This label contains a string indicating the Video firmware version downloaded in 
the selected unit. 
•  Firmware File (read-write) 
Before performing a firmware update, the complete path of the firmware file must 
be provided here. 
•  Temperature (read-only) 
This property indicates the temperature of the selected Microflex  
•  Board Version/Rev (read-only) 
This label contains a string indicating the Board Version and the Revision of the 
selected unit (Ex: 1.0/A). 
4.4.2 Audio 
 
The following properties are provided for each available audio channels of a 
selected unit. 
 
•  Module (read-only) 
NONE when module does not support audio, FXS for 2-wire loop-start 
subscriber, FXO for 2-wire loop-start line interface and Line Level for line level 
audio hardware configuration.