IKUSI ELECTRONICA S.L. RAD-RF ユーザーズマニュアル

ページ / 20
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 3  
Receiver to Power Electric Circuit connection 
 
The contacts of KSTOP1 and KSTOP2 (KSTOP1+KSTOP2=STOP)
 
relays are in series 
and must be connected to the main contactor coil circuit. 
 
The K2/START is activated once the start-up command is held down. 
 
The K1/SAFETY relay is a security relay which is activated when any of the other 
function control relay are activated. 
 
The receiver is a class II device, according EN50178, containing a functional earth 
connection. A (in Europe green-yellow) ground cable is not recommended for this earth 
connection. 
 
The power supply and relays must be protected against current overload with convenient 
electric devices, limiting the maximum input/ output current to their limits: 1A fuse is 
provided in the receiver circuit board for power supply.  8A fuse(s) has to be provided in 
the crane control panel for the for the output relays. 
RADS11 and RADF13 Users Manual ver1.2.doc 
KCI Hoists Corp.  reserves the right to modify this information without prior notification. 