Radwin Ltd. AMWL1240 ユーザーズマニュアル
Chapter
2 Installation and Setup
WinLink 1000 Installation and Operation Manual
2-8
Installation and Setup
to issue traps. Refer to
Chapter 3
,
Community String
on page
for a
complete description.
1. From the Start menu, point to Programs, point to WinLink 1000
Manager, and then click WinLink 1000 Manager.
The password/IP request dialog appears.
Error! Not a valid link.
Figure
2-3. Login Screen
2. Select the suitable option for the IP Address field:
Enter the IP address of the ODU —
default value 10.0.0.120
.
The IP address is defined later during link configuration.
(optional) If user is connected directly to the IDU LAN port, use
the adjacent list arrow to select Local Connection.
the adjacent list arrow to select Local Connection.
Error! Not a valid link.
Figure
2-4. Login vial Local Connection Screen
3. Enter the password
Default password –
admin
(see Chapter 4 for
Changing the
Password
)
The WinLink 1000 Manager Main menu is displayed (see
Figure 2-5
).
Error! Not a valid link.
Figure
2-5. Main Menu
Aligning the WinLink 1000 ODUs
Perform the WinLink 1000 ODU alignment using the Buzzers located
inside the ODUs. Alignment of a WinLink 1000 link must be performed
by two people simultaneously, at site A and at site B.
inside the ODUs. Alignment of a WinLink 1000 link must be performed
by two people simultaneously, at site A and at site B.
Î
To align the ODUs via ODU Buzzer:
1. Verify that power is connected to the IDUs at both sites.
Do not stand in front of a live radio terminal.
2. Align the site A ODU in the direction of the site B ODU.
3. Align the site B ODU in the direction of the site A ODU
3. Align the site B ODU in the direction of the site A ODU
Warning