Radwin Ltd. AMWL1240 ユーザーズマニュアル
WinLink 1000 Installation and Operation Manual
Chapter
5 Diagnostics and Troubleshooting
PM
Troubleshooting 5-7
Table
5-2. Troubleshooting with WinLink 1000 LEDs
Led Status
Remedy
PWR
Off
Check that AC adapter is connected to the IDU
and the AC power outlet.
and the AC power outlet.
IDU
Orange
Check that the IDU/ODU cable is properly wired
and connected.
and connected.
ODU
Red
Check that the IDU/ODU cable is properly wired
and connected.
and connected.
Orange
Complete the installation procedure from the
management software.
management software.
AIR I/F
Red
Check the ODU Antenna alignment. Check that
the radio configuration of both site A and site B
units are the same (channel and SSID).
the radio configuration of both site A and site B
units are the same (channel and SSID).
Off
Check the TDM service configuration in the NMS.
Orange
Check that the system is not in loopback mode.
Check the site B IDU ports and cables and site B
external equipment.
Check the site B IDU ports and cables and site B
external equipment.
SERVICE
Red
Check the site A IDU ports, cables and external
equipment.
equipment.