 PM 
Troubleshooting 5-7 
Table 
 
5-2.  Troubleshooting with WinLink 1000  LEDs 
Led Status 
Remedy 
PWR  
Off 
Check that AC adapter is connected to the IDU 
and the AC power outlet. 
IDU  
Orange 
Check that the IDU/ODU cable is properly wired 
and connected. 
ODU  
Red 
Check that the IDU/ODU cable is properly wired 
and connected. 
Orange 
Complete the installation procedure from the 
management software. 
AIR I/F  
Red 
Check the ODU Antenna alignment. Check that 
the radio configuration of both site A and site B 
units are the same (channel and SSID). 
Off 
Check the TDM service configuration in the NMS. 
Orange 
Check that the system is not in loopback mode. 
Check the site B IDU ports and cables and site B 
external equipment. 
SERVICE  
Red 
Check the site A IDU ports, cables and external 
equipment.