5  Diagnostics and Troubleshooting 
WinLink 1000  Installation and Operation Manual 
5-6 Troubleshooting
 
 
Testing 
Equipment 
Management 
Station
E1
Interface
/T1
E1
Interface
/T1
Local ODU
Inband Loopback
Activation Command
Remote ODU
 
Figure 
 
5-5.  Remote External Loopback 
Local Internal Loopback 
Local WinLink 1000  can be set to close an internal loopback to test 
connection between the local and remote units, remote E1/T1 port and 
its connection to the remote side user equipment. In this mode, data 
coming from the remote user equipment is looped back to it (see 
Figure 
 
5-6
). This loopback is initiated by an inband command sent 
from a management station connected to the local unit. 
Testing 
Equipment 
Management 
Station
Local ODU
Inband Loopback
Activation Command
Remote ODU
E1/T1
Interface
E1
Interface
/T1
 
Figure 
 
5-6.  Local Internal Loopback 
5.4  Troubleshooting 
The WinLink 1000  LEDs show faults in the system or the link. Use 
Table 
 
5-2 to diagnose the fault.