Troubleshooting and Maintenance
Test All
Test All runs the entire test sequence and displays the results.
1.
Press 1 when the ViVOpay AR Diagnostics screen is displayed. All of the tests are run 
in sequence and the results are displayed. See each individual test for information. 
LCD Test
The LCD test turns the pixels on/off and checks screen clarity to verify that the LCD screen is working 
properly. The results will be displayed on the LCD. 
1.
Press 2 from the ViVOpay AR Diagnostics screen. The AR LCD Test screen is 
displayed.
2.
Press 1. The display will fill with alpha characters on line one and numeric characters on 
line 2. 
3.
Press ENTER if the correct screen is displayed otherwise press CANCEL to fail the test. 
The AR LCD Test screen is displayed.
4.
Press 2. All pixels should be turned off and the screen should be bright. 
5.
Press ENTER if the correct screen is displayed otherwise press CANCEL to fail the test. 
The AR LCD Test screen is displayed.
6.
Press 3. Both lines of the display are filled with the # character.
7.
Press ENTER if the correct screen is displayed otherwise press CANCEL to fail the test. 
The AR LCD Test screen is displayed.
8.
Press 4. You can change the contrast by pressing the 7 key for more contrast or the 9 key 
for less contrast. A numeric value (20 high to 42 low) for the contrast is displayed.
9.
To save an new contrast setting, press ENTER and press the keys as instructed by the 
prompt. 
10. Press CANCEL to exit back to the main menu.
Touch Screen Test
The Touch Screen test does not apply to the ViVOpay 8100e. Test All skips this test or press 
CANCEL to abort this test.
Keypad Test
This test asks you to enter each of the keys in sequence to verify that the keypad is working correctly. 
The results will be displayed on the LCD. 
AR
 LCD Test
1 Test Character Display (not run)
2 Test all pixels OFF (not run)
3 Test clarity of display (not run)
CANCEL(X) Exit to main menu
Select Test with 1, 2, or 3 and:
Press ENTER (O) to pass test
Press CANCEL (X) to fail test
4 Set 8100 Contrast (not run)