ZTE Corporation R8854S2600 ユーザーズマニュアル

ページ / 22
 
ZXSDR R8854 S2600 Product Description
 
ZTE Confidential & Proprietary
 
17 
For a description of the external interfaces on the right side of the R8854 S2600 chassis, 
Table 3-11 Description of the External Interfaces on the Right Side 
No. 
Label 
Interface 
Interface Type/Connector 
OPT1 
Communication between 
RRU and BBU, or RRU 
cascading interface 
LC-type optical interface (IEC 
874) 
OPT2 
RRU cascading interface 
LC-type optical interface (IEC 
874) 
PWR 
Power input interface 
2-pin customized connector 
Additionally,  R8854  S2600  provides  6  LED  indicators.  The  indicators  on  the  R8854 
S2600 panel indicate the operating status of the RRU. 
3.5 
Transmission   
R8854 S2600 is connected to BBU through CPRI interfaces. For more information about 
CPRI interfaces, refer to Table 3-12. 
Table 3-12 CPRI Interfaces 
Item 
Value 
Interface Type 
Speed 
Standard 
CPRI interface 
SFP (LC) 
9.8 Gbps 
[2]
 
CPRI V5.0 
3.6 
Working Environment Indices 
Table 3-13 Environment Indices 
Item 
Characteristics 
Temperature   
-40 to +55 °C 
                                                   
2
  The speed here refers to the max capability of the hardware. The specific speed depends on the optical module 
configuration.