3  Setting up the System 
3.1  Initial settings for an MCU 
3.1.1 Mobile PTP and PTMP system 
1)  A mobile point-to-point or P2MP system should contain at least 2 units.  
2)  In a system one MCU will be a master and at least one should be set as slave (P2P), or more 
(P2MP).  
3)  Setting  up  a  Master/Slave  is  done  by  burning  the  relevant  ZIP  file  (Mobilicom    will  provide 
both Master and Slave Files) (MC-EMA will support such configuration in the future)   
4)  After setting up Master/Slave the unit can be boot up and set up the rest of the parameters via 
the EMA.   
5)  The rest of the parameters are set as a part of the profile customized for a client. 
6)  All these stages are typically done in the lab prior to shipment enabling easily plug-and play 
by  the  customer  (typically  attenuators  are  connected  to  the  RF  ANT  jacks  in  a  basic  unit 
configuration without antenna). Nevertheless, this procedure can be done after installation as 
well. 
3.2  Installation 
1)  The MCU-100 can be installed in two ways: 
o  Installed using the 4 peripheral mounting holes 
– mainly used on large surfaces such as 
walls, car top or ceilings. Schematics can be supplied by Mobilicom 
o  Installed  using  the  back  mounting  holes  via  mounting  arm  (such  as  MT-120018/A) 
– 
mainly used on poles. Schematics can be supplied by Mobilicom. 
2)  Antennas installation: 
The antennas should be as close to the MCU-100 as possible and can be connected to it 
directly into its ANT powers #1 and #2.  
3)  Cables  should  be  chosen  according  to  their  attenuating  (best  ones  should  be  chosen)  and 
flexibility  (according  to  the  path  they  pass  through).  Each  cable  should  have  TNC-Male 
connector on one end and connector matching to the antenna on the other (most common are 
N-Type Male/Female). Recommended cable standards can be supplied by Mobilicom. 
7)  Before  powering  up  the  MCU-100  the  antennas  should  be  connected  to  it  (alternatively 
attenuators can be connected to the RF ANT jacks for basic setups).