7.5
Power Requirements
The DC wide mouth power supply supports from -18 VDC to -60 VDC. The optional AC
power supply is auto-sensing in the 90 to 132 V and 180 to 264 V ranges.
power supply is auto-sensing in the 90 to 132 V and 180 to 264 V ranges.
Table 38: Spec.: RedMAX 4C Power Dissipation (Watts)
Sectors without
Redundancy
Sectors with Redundancy
& Diversity
Modules
1 3 4 6 1 3 4 6
BBM
50 150 200 300 100 200 300 400
TCM
30 30 30 30 60 60 60 60
Cooling
Module 50 50 50 50
100
100
100
100
RRH
150 450 600 900 150 450 600 900
Total
280 680 880 1280 410 810 1060 1460
7.6
Heat dissipation (Shelf)
Table 39: Spec.: Heat Dissipation for SC-1000 Shelf (IDU) in BTU/Hour
Sectors without
Redundancy
Sectors with Redundancy
& Diversity
Modules
1 3 4 6 1 3 4 6
BBM
170 510 680 1020 340 680 1020 1360
TCM
100 100 100 100 200 200 200 200
Fan
Tray
(CU) 170 170 170 170 170 170 170 170
Total
440 780 950 1290 710 1050
1390
1730
7.7
Heat dissipation (Remote Radio Head)
Table 40: Spec.: Heat Dissipation for RRH (ODU) in BTU/Hour
Sectors without
Redundancy
Sectors with Redundancy
& Diversity
Modules
1 3 4 6 1 3 4 6
RRH
400 1200 1600 2400 400 1200 1600 2400
Total
400 1200 1600 2400 400 1200 1600 2400