Tagsys S.A. LSP3CLEAR-L40 ユーザーズマニュアル

ページ / 68
 
20/68 
Revision 2.1 
December 2009 
 
4.1.2  Electrical Safety Rules 
The L-SP3 is powered up via a Mains Supply IEC Cord. 
 A  group  of  up to  5  Pedestals  can  be  daisy  chained  and  powered  via  a  single  IEC  power 
cord connected to a wall socket. The mains wall socket should provide at least 2 Ampere and be 
protected by a differential circuit breaker limiting the current to 5 Ampere maximum. 
 
Figure 3
 here below shows how to connect the L-SP3 pedestals to the mains. 
 
Figure 3: Safety Electrical Installation Using Power Cord 
Wall 
Socket
IEC Power Cord
LSP3 Pedestals Aisle
 
 
 
4.1.3  Network cable installation 
The  L-SP3  Pedestal  delivery  package  does  not  include  an  Ethernet  cable  to  connect  to  a  Local 
Area Network for remote operation.  We recommend the use of a Shielded Ethernet cable, UTP-
Cat 5.  
 
 
The electrical installation must be carried on by qualified personnel only. 
For each country where installation takes place, an adequate IEC power 
supply Cord must be used, fitting the local wall socket layout.