Installing the Reader 
 
April 2008 
Revision 2.2 
19/41 
 
•  Reset Procedure 
To reset the Ethernet module 2 procedures are available: 
Reboot the device: it is used to reinitialize the communication with your network. 
Reset the device to TAGSYS default factory settings: it is used when you can no more 
communicate with the reader due to wrong WIFI settings. 
Both reset procedures are available by software via the WEB or TELNET interface. 
 
Reset 
Description 
Reboot 
While the reader is supplied, push the reset button with a thin object and 
release it. Wait for the reader start up. 
Reset To 
TAGSYS Factory 
defaults 
This procedure reset the entire device configuration (including network 
settings) to the TAGSYS factory defaults. 
Unplug the reader power supply 
Push the reset button 
Plug the reader power supply 
Keep the reset button pressed until the yellow LED blinks once and 
3 times. 
Release the reset button 
Unplug the power supply and plug it again 