Tagsys S.A. MEDIOP101ETHER ユーザーズマニュアル
Installing the Reader
April 2008
Revision 2.2
19/41
• Reset Procedure
To reset the Ethernet module 2 procedures are available:
-
Reboot the device: it is used to reinitialize the communication with your network.
-
Reset the device to TAGSYS default factory settings: it is used when you can no more
communicate with the reader due to wrong WIFI settings.
communicate with the reader due to wrong WIFI settings.
Both reset procedures are available by software via the WEB or TELNET interface.
Reset
Description
Reboot
While the reader is supplied, push the reset button with a thin object and
release it. Wait for the reader start up.
release it. Wait for the reader start up.
Reset To
TAGSYS Factory
defaults
This procedure reset the entire device configuration (including network
settings) to the TAGSYS factory defaults.
settings) to the TAGSYS factory defaults.
-
Unplug the reader power supply
-
Push the reset button
-
Plug the reader power supply
-
Keep the reset button pressed until the yellow LED blinks once and
3 times.
3 times.
-
Release the reset button
-
Unplug the power supply and plug it again
-
Wait for reader start up.