Viewsonic Pro9500 PRO9500 ユーザーズマニュアル

製品コード
PRO9500
ページ / 289
Installation
236
ViewSonic 
Pro9500
NOTES for all users
  • For details on PERFECT FIT, refer to PERFECT FIT 
of EASY MENU or OPTION menu in the Operating Guide.
• When arranging the projectors side by side (Style 2), it is also necessary to 
adjust the image position of one projector in accordance with the other projector 
as explained above. 
• It is strongly recommended to use a flat screen.  If a curved or skewed screen 
is used, it is very difficult to align the two images even if you use the pin/barrel 
adjustment of PERFECT FIT.
• Even through fine adjustment of the images from the two projectors, it may 
not be possible to superimpose the images well enough depending on the input 
signals.  In this case, try the following methods.
-  Press the 
AUTO button on the remote control or execute AUTO ADJUST 
EXECUTE (Operating Guide → IMAGE menu) on each of the projectors.
-  Adjust H POSITION and V POSITION (Operating Guide → IMAGE menu) on 
each of the projectors.
-  Check the RESOLUTION setting in the INPUT menu, and change to the 
same setting if the setting differs between Main and Sub. (Operating Guide → 
INPUT menu
5.
 Using PERFECT FIT on Set B, adjust the im-
age size and position of Set B to superimpose 
well to the image of Set A.  It is recommended 
to adjust in the following ways.
(1) Roughly adjust the four corners in the 
order below.
Top left → Top right → Bottom right → Bottom left
(2) Fine adjust the four corners in the same way.
For Simple Stack users
1.
 Press the 
MENU button on the remote control to display the menu on Set A.
2.
 Use the ▲/▼/◄/► buttons to open the 
TEMPLATE dialog, then select STACK on the 
dialog. (Operating Guide → SCREEN menu)
3.
 Press the 
MENU button on the control panel of 
Set B to display the menu.
4.
 Use the ▲/▼/◄/► buttons to select 
PERFECT FIT from EASY MENU, or the 
SETUP menu of ADVANCED MENU. (Operat-
ing Guide → EASY MENU or SETUP menu)  
PERFECT FIT dialog appears on screen.
STACK of TEMPLATE
PERFECT FIT dialog 
on STACK of TEMPLATE