Alvarion Technologies Ltd. BMAX-BA36 ユーザーズマニュアル

ページ / 334
 
158
Operation
Chapter 4 - Operation and Administration
‘
Downlink Basic Rate
‘
Minimum Number of Sub-Channels
„
ATPC Parameters (as defined in the Base Station-Cell menu):
‘
ATPC Enable/Disable
‘
Optimal Uplink RSSI (dBm)
„
Voice Parameters (not applicable for units operating in IP CS Switching Mode):
‘
Maximum Number of Voice Calls
‘
Active Voice Calls
4.9.5.2
Unit Control
The AU Unit Control menu enables resetting the AU and managing the SW 
versions of the module.
The Unit Control menu includes the following options:
„
Reset
„
Set Factory Defaults
„
SW Version Control
4.9.5.2.1
Reset Unit
Select this option to reset the unit. To avoid unintentional reset, you will be 
prompted to confirm the reset request. Changes to some of the configurable 
parameters are applied only after reset. Refer to 
 for information on 
which parameters are changeable in run time and which changes are applied only 
after reset. 
NOTE
The Optimal Uplink RSSI is configured at the Base Station level for all AUs. The permitted range for 
configuration is from -90 to -60 dBm. The actual range that can be accepted by AUs operating in 
TDD mode is -80 to -74 dBm. If a value higher than -74 dBm is configured at the Base Station level, 
the actual value in the AUs will be -74 dBm (hence the actual default at the AUs is -74 dBm). If a 
value lower than -80 dBm is configured at the Base Station level, the actual value in the AUs will be 
-80 dBm. If the configured value differs from the actual one, both will be shown, starting with the 
configured value.