8M074X01-01  Rev.1
                                                                                10                                                  
1.  Make sure that the Futurecom Channel Module Programming Software is installed as
described earlier.
 
2.  Connect the Channel Module as described in Channel Module Connections section and
power it up.  It is recommended that the donor site transmitter is disabled during Channel
Module settings!
 
3.  Connect the personal computer to the Channel Module front panel RS-232 connector with
Futurecom CM Serial Programming Cable, part number 7W038X61-01.
 
4.  Select the hard disk drive where the programming software is located.  To select e.g. drive C
type C: <Enter>.  Switch to FUTURCOM directory by typing
 
CD \FUTURCOM <Enter>.
 
5.  Start the Channel Module Programming Software by typing CMD <Enter>.
 
6.  Select “Options” field and then select “RS-232” using cursor keys.  Press <Enter>.  Using
cursor keys and  <Page Up>,  >Page Down> and numeric keypad  <->,  <+> select the
following settings:
Access to unit
Direct
Baud Rate
9600 b/s
Data Bits
8
Stop Bits
1
Parity
None
Comm. Port
Com-1 or Com-2 depending on the personal computer
Baud rate scanning
disable
Press  <Esc>.  With cursor keys select  Yes as an answer to  Would you like to update
config. file
.  Press <Enter>.