Adtran TRC6410L2X ユーザーズマニュアル

ページ / 130
TRACER 6000 Series Integrated System Manual
Section 5  User Interface Guide
612806420L1-1D
Copyright © 2005 ADTRAN, Inc.
89
>RF L
INK
 M
ANAGEMENT
 B
RIDGE
 C
ONFIGURATION
 > I
NACTIVITY
 T
IMEOUT
Defines the amount of time that an Ethernet address is maintained in the bridge table. A shorter time 
produces a more dynamic bridge table, allowing addresses to change network segments without causing 
extra forwarded traffic. A longer time reduces the amount of unnecessarily forwarded traffic (due to 
unknown Ethernet addresses), but causes the bridge table to respond more slowly to a MAC address 
switching network segments. Valid choices are: 
SEC
 (default), 
15 
SEC
30 
SEC
MIN
, and 
MIN
.
> S
YSTEM
 A
LARMS
Figure 35 shows the System Alarms menu page, which displays system alarm information for the link, fans, 
and temperature of the local and remote systems.
Figure 35.  System Alarms
> S
YSTEM
 A
LARMS
 > L
INK
 A
LARM
Indicates the current status of the RF link between the local and remote TRACER 6410 systems. 
L
INK
 U
P
 
indicates that the system detects a valid RF link and 
L
INK
 D
OWN
 indicates that the system does not detect a 
valid RF link.
> S
YSTEM
 A
LARMS
 > F
AN
 A
LARMS
Displays operational alarms for the system fans. An alarm is indicated when the system detects that the 
fan(s) rotational speed is below nominal operation and when the fan(s) is not functioning properly. Figure 36 
on page 90
 provides an example fan alarm.
System Alarm information is only available for the TRACER 6410.