Advanced Configuration
Tsunami
®
 800 & 8000 Series - Software Management Guide 
180
This screen is classified into two categories: Intra Cell Blocking and Security Gateway. Given below are the configuration
details.
: Intra Cell Blocking is configurable only in Bridge mode. When you change the device from Bridge to Routing mode 
or vice-versa, Intra-Cell Blocking stops or starts working only after device reboot.
5.10.6.1 WORP Intra Cell Blocking Group Table
The user can form groups of SUs at the BSU which define the filtering criteria. All data to/from SUs belonging to the same
group are bridged. If an SU does not belong to any group, the BSU discards the data.
By default, a BSU supports 16 groups and each group can contain a maximum of 240 SUs. Please note that a single SU can be
a member of all the existing groups.
To view and configure the Intra Cell Blocking Group table, navigate to ADVANCED CONFIGURATION > FilteringWORP
Intra Cell Blocking 
Group Table. The WORP Intra Cell Blocking Group Table screen appears:
Figure 5-112 WORP Intra Cell Blocking Group Table
Parameter
Description
Intra Cell Blocking
Status
By default, Intra Cell Blocking is disabled on a BSU. Select Enable to enable the feature 
and then Click OK and then COMMIT.
Security Gateway
Status
By default, Security Gateway is disabled on a BSU. Select Enable to enable the feature.
MAC Address
Represents the MAC address of the security gateway. This gateway routes the packets 
transmitted by the SU to the different BSUs to which it belongs.
After configuring the required parameters, click OK and then COMMIT.