7.11.3.1 sFlow Receiver Configuration
The Receiver Configuration page allows you to configure sFlow Receiver(s), which receives samples from all agents on the
network, combines and analyzes the samples to produce a report of network activity.
To configure sFlow Receiver, navigate to MONITOR > Tools > sFlow and select Receiver Configuration tab. 
Given below is the table which explains sFlow parameters and the method to configure the configurable parameter(s):
Click Apply, to save the sFlow Receiver configuration parameters.
Once the Receiver configurations are done, either Packet Flow sampling or Counter Polling Sampling or both can be started.
Enabling sampling effects the system performance and hence care should be taken in setting the right values for 
Timeout and Max Datagram Size.
When the Owner string is cleared, the Flow Sampling and Counter Polling stops.
7.11.3.2 Sampling Configuration
To configure and start packet flow sampling, do the following:
1. Navigate to MONITOR > Tools > sFlow and select Sampling Configuration tab. 
Parameter
Description
S.No.
Represents the Receiver index number. Please note that the number of indexes depends 
on the Ethernet interfaces your device supports.
Owner
Enter a string, which uniquely identifies the sFlow Receiver.
Time Out
Enter a value ranging from 30 to 31536000 seconds (365 days) in the Time Out box.
The sFlow Agent sends sampled packets to the specified sFlow Receiver till it reaches zero. 
At zero, all the Receiver parameters are set to default values.
Max Datagram Size
Enter the maximum size of a sFlow datagram (in bytes), which the Receiver can receive, in 
the Max Datagram Size box. By default, the maximum datagram size is set to 1400 
bytes. It can range from 200 to 1400 bytes.
Address Type
The address type supported by sFlow Receiver is ipv4, which is by default selected.
: Only IPv4 is currently supported.
Receiver Address
Enter the sFlow Receiver’s IP address in the Receiver Address box.
Receiver Port
By default, the sFlow Receiver listens to the sFlow datagrams on 6343 port. To change the 
port, enter a valid port ranging from 0 to 65535 in the Receiver Port box. 
Datagram Version
The sFlow datagram version used is 5.