Proxim Wireless Corporation XB92WFR ユーザーズマニュアル

ページ / 336
Advanced Configuration
Tsunami
®
 800 & 8000 Series - Software Management Guide 
58
: In routing mode, the Primary and Secondary IP Address cannot be configured as IPv6 addresses.
After configuring the required parameters, click OKCOMMIT and then REBOOT.
To obtain dynamic IP address of the SU over WORP,
Scenario 1: When BSU and SU are in Bridge Mode with DHCP Client enabled in SU, and if external DHCP 
server is running behind BSU, then SU will get the IP Address over WORP.
Scenario 2: When BSU and SU are in Bridge mode with DHCP client enabled in SU, and if BSU has an 
embedded DHCP server running on the wireless interface, then SU will get the IP address from BSU.
Scenario 3: When BSU is in Routing Mode and SU is in Bridge mode, and DHCP server is in a different 
network than SU, then configure DHCP relay in BSU to get the IP for SU over WORP. 
Scenario 4: When BSU is in Routing mode and SU in Bridge mode, and if BSU has an embedded DHCP server 
running on the wireless interface, then SU will get the IP address from BSU.
5.2.1.3 Routing Mode with PPPoE Client Enabled
To configure the IP parameters of the device when configured in Routing mode with PPPoE client enabled, navigate to
ADVANCED CONFIGURATION > Network. The IP Configuration screen appears:
Parameter
Description
Primary IP Address
Represents the IP Address of the Primary DNS Server. 
Secondary IP Address
Represents the IP Address of the Secondary DNS Server. 
: IP Configuration in Routing mode with PPPoE Client enabled is applicable only in SU mode. See 
End Point (SU Only)