5.3.4 Depth calibration  
¾  Press the 
 button to activate a window where you can write the 
exact depth of the pipe or cable (if it is known) from another source such, as  
technical maps or from opening manhole covers. 
 
¾  Otherwise, press the 
 button to activate the following window, 
 
Select the correct propagation speed by using the 
 and 
 buttons to 
adjust the white-line curve to the shape of the hyperbola. 
 
 
NOTE
 
 
In both cases, you have to select one of the icons shown in Fig. 5-12 to confirm 
the depth of the identified pipe. This operation can be repeated several times 
during the acquisition: a symbol will appear at calibration points describing the 
type of the characteristics of the detected pipe. 
 
 
¾  Press the 
 button to finish the scan while remaining in the open survey. 
¾  Press the 
 button to save the scan file onto the computer hard disk (in the 
C:\2150GR\Mission directory); you can continue the same scan by moving the 
trolley in the original direction. 
¾  Press the 
 button to finish the scan and go back to the main menu shown 