4. Log out (see Logging out of the CTM web interface, page 43).
5. Select
Change Password from the navigation sidebar.
6. Enter your user name and compose a password.
Note: This password does not become your new password.
Configuring the Reader to recover automatically to the primary side
The Reader can be configured to automatically activate the primary side once a failure causing a
switchover to the secondary side has cleared.
Prerequisites: Connect the service laptop to the Reader configuration port to access the CTM web
Prerequisites: Connect the service laptop to the Reader configuration port to access the CTM web
interface. Refer to Connecting a service laptop to the Reader, page 40.
Note: You must have Advanced User permissions.
Note: You must have Advanced User permissions.
1. Set the SPM redundancy mode switch to the
AUTO position.
2. From the CTM web
Main Page, select the Configuration link on the left panel of the screen.
Result: The following Configuration page appears.
3. Select the
Auto Recovery To Prime check box.
4. Press
Enter to accept the selection.