1027144– 0001  Revision D
Commissioning the RT   7–11
RT installation
10.
Observe the reading on the voltmeter as you fine adjust the
azimuth and elevation (steps 11 and 12):
11.
Fine adjust the azimuth:
a.
Using a wrench, slowly rotate the fine azimuth
adjuster (shown in figure 7-7).
b.
Adjust until you see the highest obtainable voltage
reading on the voltmeter.
T0009034
Fine azimuth
adjuster
Fine elevation
adjuster
Figure  7-7
Fine azimuth adjuster and fine elevation adjuster
12.
Fine adjust the elevation:
a.
Using a wrench, slowly rotate the fine elevation
adjuster (shown in figure 7-7).
b.
Adjust until you see the highest obtainable voltage
reading on the voltmeter.
The antenna is properly pointed when the peak
voltage is between 0.2 volts and 3.9 volts, with no
oscillation.
c.
When the peak voltage reading remains steady
between 0.2 volts and 3.9 volts, tighten the azimuth
and elevation locking nuts (figure 7-5) to 
16 foot–pounds (21.7 Newton–meters) torque.
If you cannot obtain a steady voltmeter reading
between 0.2 volts and 3.9 volts, refer to table 7-1 for