EMS Technologies Canada Ltd. HSD-X ユーザーズマニュアル

ページ / 366
Page 1–7
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
(b) Combined Mode
For Combined Mode installations, the minimum requirement for HSD 
Control-Processor software is version 5.4 (or later) to use ARINC 429 data from 
the Honeywell SDU. Version 5.4, Control-Card software is available via HSD 
Service Bulletin, 1110-SB-0012. The minimum requirements and 
recommendations for software are shown in Table 1–7.
(c) Cooperative Mode
For Cooperative Mode installations, the minimum requirements and 
recommendations for software are shown in Table 1–8.
(d) Selective Mode
Selective Mode is a non-standard installation and it is not a recommended mode 
of operation. Selective Mode has been superseded by Combined Mode 
operation for MCS series SATCOM and with Cooperative Mode operation for 
SAT-906 series SATCOM.  It is recommended that all systems operating in 
Selective Mode are upgraded to support Combined or Cooperative Mode as 
applicable.
For Selective Mode installations, the minimum requirements and 
recommendations for software are shown in Table 1–9.
 Table 1–7. Combined Mode Recommended Software Requirements
Unit
Part 
Number 
Software 
PN
Software 
Type
Minimum 
Software 
Req’t
Recommended 
Software
HSD-128 1110-A-0001
1110-A-0060
1110-A-0150
1110-A-0160
1110-A-0048 Control 
Processor
5.7
7.5 (or later)
1110-A-0082 Channel 
Card
C35
C41 (or later)
 Table 1–8. Cooperative Mode Recommended Software Requirements
Unit
Part 
Number 
Software 
PN
Software 
Type
Minimum 
Software 
Req’t 
Recommended 
Software 
HSD-128 1110-A-0001
1110-A-0060
1110-A-0150
1110-A-0160
1110-A-0048 Control 
Processor
5.7
7.5 (or later)
1110-A-0082 Channel 
Card
C35
C41 (or later)