13
Intracardiac Electrogram
Intracardiac electrograms may be printed or displayed and event markers 
may be printed by the PRM. For detailed instructions, refer to the System 
Guide for the Guidant pulse generator being interrogated.
Using an External Recorder
To view the surface ECG traces on an external recorder, press the de-
sired speed key on the external printer/recorder while the traces are dis-
played on the PRM screen. See “EXTERNAL CABLE CONNECTIONS” 
on page 22
 for instructions on connecting the PRM to the external record-
er. Refer to the external recorder manual for instructions specific to its op-
eration.
Using an External Printer
If supported by the software application currently running, an optional ex-
ternal printer can be used. To print reports to an external printer, first con-
nect the printer to the Model 3120 PRM using the parallel cable. The ca-
ble connects the external printer to the PRM via the external printer con-
nector (Figure 2). The external printer must be connected and activated 
to allow external reports to be printed. For more information, see “Optional 
External Printer” on page 5.
Equipment connected to the external connections must comply with the 
respective IEC standards (e.g. IEC 950 for data processing equipment 
and IEC 601-1 for medical equipment).  Furthermore all configurations 
shall comply with the system standard IEC 601-1-1.  Everybody who con-
nects additional equipment to the signal input part or signal output part 
configures a medical system, and is therefore responsible that the system 
complies with the requirements of the system standard IEC 601-1-1.  If in 
doubt, Guidant Technical Services department or your local Guidant Rep-
resentative.
Quick Start
The Quick Start button is used to automatically identify and interrogate the 
implanted pulse generator. Place the telemetry wand over the pulse gen-
erator, and select the Quick Start button. A message window will appear, 
indicating one of the following conditions, based on the implanted device:
Application Startup in Progress—If the software for the implanted 
device is installed on the PRM, the PRM will identify the device, open 
the correct application, and automatically interrogate the pulse gener-
ator.
Software not installed—If the software application for the implanted 
device is available for the PRM but not installed on it, a message win-
dow will appear, identifying the device and stating that the software is 
not installed on the PRM.
Software not available on PRM—If an older model of Guidant device 
is identified, a message window will appear, informing the user that he 
or she must use a Model 2035 or 2901 programmer to interrogate and/