Elster American and Itron Actaris Commercial Meter Installation 
 
 
TDC-0823-005     100G Datalogging Installation Guide - Direct Mount 
58 
 
Proprietary and Confidential
 
 
 
 
2.  Align the endpoint so the screw holes line up with the meter's top screw holes. Carefully lower the 
endpoint on the meter with the wriggler notches lining up with the meter's wriggler teeth. 
 
Warning  The INLET label on the 100G Datalogging commercial gas endpoint must line up 
with the INLET label on the meter case. 
 
3.  Verify the bottom of the endpoint and the top of the meter meet. The endpoint housing should rest on top 
of the meter without gaps. 
 
Warning  Do not press down on the 100G Datalogging commercial gas 
endpoint if a gap exists between the endpoint and the meter. A gap may be 
caused by misalignment of the endpoint wriggler and meter wriggler's drive 
teeth. Pushing down on the endpoint could damage the endpoint wriggler or 
meter drive teeth. To eliminate a gap, slowly turn the endpoint's upper 
wriggler back and forth until the endpoint aligns with the meter's drive teeth.  
 
 
 