22. Verify that the encoder cable is in the correct
position in the cable slot of the gasket. Fully
tighten the screws in an alternating pattern.
Install utility-approved security seals and wires
as required.
Remote ERT module programming and requirements
notes
 on
page 14.
Residential module programming notes:
The ERT module is programmed based on the meter's drive rate. Take note of the index
drive rate shown on a lower dial on the index. Elster American meter index drive rates are
either 1-cubic foot, 2-cubic feet or 0.05 cubic meters (not shown below).
Commercial module programming notes:
Take note of the index drive rate shown on the index. The ERT is programmed based on the
drive rate. Elster American commercial meter index drive rates may be 5-, 10- or 100 cubic
feet. The index shown has a 10-cubic foot drive rate.
Diaphragm Meter Installation
OpenWay Riva 500G Gas ERT Module Installation Guide, Remote Mount TDC-1678-000