D-3
Appendix D
Command Quick Reference
This appendix lists the default configuration settings for the 
Encompass
TM
 4/4800 Multiprotocol Reader and its commands. 
Commands are listed both numerically and alphabetically.
Command Syntax
The command numbers consist of from 2 to 4 hex digits. The letters N or S may follow 
a command number. The letter N indicates that part of the command number is vari-
able. The letter S indicates the requirement for an alphanumeric data string that is to 
be included immediately following the command number. Hex digits (0–9, A–F) in 
either uppercase or lowercase characters may be used in data strings and for hex digits 
A–F. For more information see Chapter
Table D-1 lists factory default settings. Table D-2 on page D-6 lists, in numerical 
order, all of the commands available to users. Table D-3 on page D-16 lists the same 
commands by command name. 
Factory Default Settings
Note:  
 lists the factory default settings for the Encompass 4/4800 Multipro-
tocol Reader.
Table D-1   Encompass 4/4800 Multiprotocol Reader Default Configuration 
Settings
Parameter
Setting
Command
Operating mode
Data
00
Baud rate 
9600
1005
Stop bits 
1
1010
Parity
None
1020
Auxiliary information appended
Disabled
310
Unique ID code criteria
Separation of 1 ID
4100
Wiegand mode
Disabled
450
Alternative group select
Disabled
452