Visonic Inc. MCT442 ユーザーズマニュアル

ページ / 4
D-300273 
 
MCT
MCT
MCT
MCT----442
442
442
442    
Supervised Indoor Wireless CO Gas Detector 
Installation Instructions
1. INTRODUCTION 
The carbon monoxide (CO) detector is designed to monitor the 
CO gas level in residential dwellings and give early warning 
before potentially dangerous levels exist. The CO alarm is 
transmitted to the PowerMax+ (version F and up) or PowerMax 
Pro and presented on its display. 
The CO gas is considered to be a highly dangerous poisonous 
gas because it is colorless, odorless, tasteless and very toxic. 
Presence of CO gas inhibits the blood's capacity to transport 
oxygen throughout the body, which can eventually lead to brain 
damage. CO gas is produced by incomplete combustion of fuels 
(such as natural gas, propane, heating oil, kerosene, coal, 
charcoal, gasoline or wood) that can occur in any device that 
depends on burning for energy and heat (such as furnaces, 
boilers, room heaters, hot water heaters, stoves, grills and in any 
gasoline powered vehicle or engine).  
Before CO harmful level is reached, the detector's internal buzzer 
beeps sound periodically and the detector's red LED flashes. In 
this condition, the buzzer sound can be stopped for 6 minutes by 
pressing the TEST/MUTE switch. It will not correct the CO gas 
problem, but will temporarily silence the buzzer while you correct 
the problem. After 6 minutes, the detector restarts alarm if the CO 
level remains high.  
The detector provides 
low battery and detector 
end-of-life indications. 
Caution
: The 
detector expiry date is 
stamped on the 
detector. After the 
expiry date, the 
detector should not 
be used - do not wait 
for end-of-life 
indication!! 
Battery
(green) /
Fault
(yellow)
LED
TEST /
MUTE
BUTTON
ALARM
(red) LED
Figure 1 - General View 
The detector is continuously self-tested and has a TEST button 
that enables the user to test the detector anytime. 
Note:  The TEST/MUTE switch functions as TEST switch (in 
normal operation) or as MUTE switch (in alarm condition).
 
The tamper switch actuator (fig. 3), is pressed against the bracket 
when the unit is attached to the bracket. Removal of the unit from 
the bracket causes the switch contacts to open, creating a tamper 
event, which is reported by the transmitter to the alarm system 
control panel.
 
2. SPECIFICATIONS 
CO DETECTION 
Detection principle:
 Electrochemical cell 
Detector Active Life: 5 years maximum 
Selectable Sensitivity:  
DIP switch in EN Mode 
No warning at 30 ppm for 120 minutes, 50 ppm for 60 minutes, 
100 ppm for 10 minutes. 
Warning at 50 ppm between 60-90 minutes, 100 ppm for 10-40 
minutes, 150 ppm within 3 minutes. 
DIP switch in UL Mode 
No warning at 30 ppm for 30 days, 70 ppm for 60 minutes, 150 
ppm for 10 minutes, 400 ppm for 4 minutes. 
Warning at 70 ppm between 60-240 minutes, 150 ppm for 10-
50 minutes, 400 ppm between 4-15 minutes. 
Audible Alarm Volume: >95db at a distance of 3m (10 ft.). 
TRANSMITTER AND CODING 
Operating Frequency (MHz):
 315, 433.92, 868.95 or other 
frequency according to local requirements. 
Transmitter's ID Code: 24-bit digital word, over 16 million 
combinations, pulse width modulation. PowerCode or Zigbee 
Protocols. 
Overall Message Length: 36 bits 
Supervision: Automatic signaling at 60-minute intervals (315 
MHz version), 15-minute interval (433.92, 868.95 MHz versions) 
or according to the local standards. 
Transmitted Messages: CO gas alarm, low battery, tamper, 
sensor end of life (5 years), sensor trouble, supervision. 
Tamper Alerts: Tamper message is transmitted to the 
PowerMax+ / PowerMax Pro control panel when the detector is 
removed from its bracket .  
ELECTRICAL DATA 
Power Source:
 9 volt Lithium battery (Ultra Life #U9VL, U9VL-J). 
Current Drain: 11 µA standby, 250 µA in operation 
Battery Life Expectancy: At least 1 year (for typical use) 
Battery Supervision: Automatic transmission of battery status 
data as part of any transmitted message. 
Visual and Audible Indications: 
Visual Indication (LEDs) 
Condition
Red Yellow
Green 
Audio 
Indication 
Alarm 4 
flashes 
(*) 
4 beeps (*)  
End of Life 
/ Fault 
- 3 
flashes 
every 
60 sec. 
- one 
beep 
every 60 sec. 
Battery OK
Flashes once 
every minute 
Low 
battery 
- 1 
flash 
every 
60 sec. 
- one 
beep 
every 60 sec. 
MUTE 
button is 
pressed (to 
silent the 
alarm for 6 
minutes) 
4 flashes 
(*) 
OFF for 6 
minutes (**) 
TEST 
button is  
pressed 
1 flash 
(the 1st 
LED)  
 
1 flash 
(the 2nd 
LED) 
Flashes (the 
3rd LED) If 
CO circuit test 
and battery 
are OK - lights 
during 2 sec. 
1 beep 
*  Every 5 seconds during the first 4 minutes, every 60 sec. after 
the first 4 minutes. 
** After 6 minutes, the detector restarts alarm if the CO level 
remains high. 
Note: Long period of low battery condition may cause improper 
function. In case of End-of-Life/Fault indication, replace the 
battery and check if the End-of-Life/Fault indication still exists. If it 
still exists, stop using the detector. 
PHYSICAL DATA 
Operating Temperature:
 -10
°
C to 40
°
C (14
°
F to 104
°
F). 
Relative Humidity: 10-93% 
±
  2% RH 
Dimensions: 127 mm (5 in.) x 40 mm (1-9/16 in.) 
Weight (without battery): 180g (6.35 oz)  
 
Compliance with Standard:
 EN 50291, UL 2034, BS 7860, 
CSA-6.19-01