Visonic Inc. MKP150 ユーザーズマニュアル

ページ / 7
DE2462U 
9
VAC
Wiring
Channels
Connect the 9 VAC
power supply to the
terminal block. Route
the wiring through the
wiring channels.
Note: The power
supply is optional
 
Figure 6: Wiring 
 
4. ENROLLING/DELETING THE MKP-150 FROM THE POWERMAX+ MEMORY 
To enroll all the MKP-150 functions (for complete list see PowerMax+ Installer Guide), enter the PowerMax+ Installer Mode from the 
PowerMax+ keypad, and proceed as shown in the following illustration. 
 Note: Refer to PowerMax+
Installer Guide for details on
performing a diagnostic test
OK
(First display is READY
or NOT READY)
READY 00:00
USER SETTINGS
NORMAL MODE
ENTER CODE
1. NEW INSTL CODE
2. ENROLLING
[installer code]
INSTALLER MODE
ENROL WL 2WAY KP
ENROLL WL DEVICE
ENROLLING TYPE
[MKP-150 No. 1 to 2]
(e.g. 2)
2way kp No :
2way kp No :   2
2way kp No :   2
2way kp No: 2
Enrolling a wireless
Keypad MKP-150
                 for next
 enrolling action
<OFF> TO DELETE
press back
tamper
switch
once
(see Fig. 4)
TRANSMIT NOW
Deleting a wireless
Keypad MKP-150
2way kp No: 2
ENROLL KEYFOB
Black rectangle means
that the MKP-150 No. 2
 is already enrolled.
AWAY
OK
NEXT
NEXT
NEXT
NEXT
OK
OK
OK
NEXT
OK
NEXT
NEXT
NEXT
ENROL WL 1WAY KP
NEXT
9. DIAGNOSTICS
NEXT
 
Figure 7: Enrolling / Deleting a MKP-150 Device from PowerMax+ Memory 
 
5. DEFINING MKP-150 PARAMETERS
5.1 Installer Menu Functions 
Important: All installer settings affect only the specific keypad on 
which the settings were performed.
 
The Installer menu enables you to perform three separate 
functions, as follows: 
SUPERVISION 
The keypad transmits supervision reports periodically to the 
PowerMax+. 
The options are: 15 minutes, 1 hour and disable
PIEZO BEEP 
Here you determine whether warning beeps will sound or muted 
during exit and entry delays. 
Options: enable beepsoff when home and disable beeps
RECORD SPEECH 
This mode allows you to record up to 5 custom zone names. 
SERIAL NUMBER 
Enables reading the system serial number for support purposes 
only. 
5.1.1 To Set Supervision Time 
Make sure the system is not in Arm mode. 
The installer’s menu is accessible only to those who know the 
installer’s code, which is 9
Î9Î9Î9 by factory default.  
A.  Press the next button (
►) repeatedly until the display reads: 
I N S T A L L E R   M O D E