Climax Technology Co Ltd TMSTZB ユーザーズマニュアル

ページ / 7
 
3
 
Away Mode
 
The Thermostat can be put into Away mode when the user leaves the house by pressing the 
Away button. 
 
To  program  Away  Mode  setting,  press  and  hold  Mode  button  for  3  seconds.  You  will  first 
program Away Cool set point, press Mode button after finish setting to program Away Heat 
set point, the Cool set point must be at least 2℃  higher then Heat set point. Press Mode 
button again to program Fan setting when done. 
 
 
Fan Setting
 
 
When in Fan setting, press UP or Down button to select fan option between Always on or 
Auto mode.
 
Always On (        icon steady on) – The fan is always turned on except under Off Mode 
Auto mode (        icon flash) – The fan will be turned on according to Away, Cool and Heat 
mode setting. 
 
Off Mode
 
The  Thermostat  can  be  put  into  Off  mode  by  pressing  and  holding  the  Away  button  for  3 
seconds. When under Off mode, the Thermostat stop all function and only display current time. 
 
Time / Temperature Display / HVAC Type Setting:
 
Press and hold the Mode button for 10 seconds to enter setting mode. The time on LCD display 
will begin to flash: 
 
Use the Up  and Down  buttons to select time and Mode  button to proceed to next option. 
Available options include: 
 
1. 
Weekday 
 
2. 
Hour 
 
3. 
Minute, 
 
4. 
AM/PM or 24-hour format display. (You can only change the time display format when 
the time is set to between 1:01~12:59)
 
5. 
Celsius or Fahrenheit display
 
6. 
HVAC type: Type 1 = Gas/Electric, Type 2 = Heat Pump(O), Type 3 = Heat Pump(B). 
 
Factory Default HVAC Type = 1 Gas/Electric 
  HVAC Type 
   
According  to  the  HVAC  system  in  the  home  environment,  select  the  HVAC  type  in  Thermostat 
setting.   
Type 1: General Gas/Electric HVAC system 
Type 2: HVAC system with Reversing Valve which operates during Cooling (Heat Pump “O”) 
Type 3: HVAC system with Reversing Valve which operates during Heating (Heat Pump “B”) 
  Remote Control 
   
After the Thermostat joins a ZigBee network, you can control the Thermostat via ZigBee network 
coordinator  or  gateway.  Please  refer  to  your  ZigBee  coordinator/gateway  manual  for  more 
information.   
The following functions are only available for setting via ZigBee coordinator and gateway: 
 
Schedule:
 
You can only program Schedule configuration via ZigBee network coordinator/gateway.   
Schedule  Setting:  Up  to  5  schedules  can  be  programmed  for  every  weekday  with  Mode, 
Setpoint and Start time. 
Schedule Control:   
Normal - The Thermostat will execute programmed schedule setting accordingly. 
Hold  –  The  Thermostat  will  bypass  currently  timed  schedule  and  perform  the  next  schedule 
when it begins 
No Schedule – The Thermostat will not execute any set schedule until it is set to Normal again. 
  Temperature Detection 
   
 
The Thermostat has built-in temperature sensors and will display the temperature reading on 
the LCD display 
 
The  Thermostat  will  transmit  temperature  signals  regularly  according  to  setting.  The  factory 
default interval is 10 minutes. 
 
When the temperature changes by +/- 2˚C, the Thermostat will also transmit a signal. 
 
You can also press the ZigBee Network Button once to transmit a temperature signal manually.