Climax Technology Co Ltd TMSTZB ユーザーズマニュアル

ページ / 7
 
5
Appendix
(For developers only.)
 
 
Thermostat Cluster ID 
Device ID: ZCL_HA_DEVICEID_THERMOSTAT 0x0301 
Endpoint: 0x01 
Server Side 
Client  Side 
Mandatory 
Basic (0x0000) 
Identify(0x0003) 
Identify(0x0003) 
 
HVAC THERMOSTAT (0x0201) 
 
Optional 
None 
None 
 
Attribute of Basic Cluster Information 
Identifier 
Name 
Type 
Range 
Access
Default 
Mandatory 
/ Optional
0x0000 
ZCLVersion 
Unsigned 
8-bit 
integer 
0x00 –0xff 
Read 
only 
0x01 
0x0001 
ApplicationVersion 
Unsigned 
8-bit 
integer 
0x00 –0xff 
Read 
only 
0x00 
0x0003 
HWVersion 
Unsigned 
8-bit 
integer 
0x00 –0xff 
Read 
only 
0x0004 
ManufacturerName 
Character 
String 
0 – 32 bytes 
Read 
only 
Climax 
Technology 
0x0005 
ModelIdentifier 
Character 
String 
0 – 32 bytes 
Read 
only 
(Model Version) 
0x0006 
DateCode 
Character 
String 
0 – 16 bytes 
Read 
only 
 
 
0x0007 
PowerSource 
8-bit 
0x00 –0xff 
Read 
only 
 
0x0010 
LocationDescription 
Character 
String 
0 – 32 bytes 
Read / 
Write 
 
0x0011 
PhysicalEnvironment 
8-bit 
0x00 –0xff 
Read / 
Write 
0x00 
0x0012 
DeviceEnabled 
Boolean 
0x00 –0x01 
Read / 
Write 
0x01 
 
Attribute of Identify Cluster Information 
Identifier 
Name 
Type 
Range 
Access 
Default 
Mandatory 
/ Optional
0x0000 
IdentifyTime 
Unsigned 
16-bit integer
0x00 –0xffff 
Read / 
Write 
0x0000 
 
Attribute of Thermostat Cluster Information 
Identifier 
Name 
Type 
Range 
Access 
Default 
Mandatory 
/ Optional
0x0000 
LOCAL_TEMPERATURE 
16-bit 
0x954d – 
0x7fff 
Read 
only 
0x0000 
M 
0x0003 
MIN_HEAT_SETPOINT_LIMIT 
16-bit 
0x954d – 
0x7fff 
Read 
only 
0x01F4 
O 
0x0004 
MAX_HEAT_SETPOINT_LIMIT 
16-bit 
0x954d – 
0x7fff
Read 
only 
0x0DAC 
O 
0x0005 
MIN_COOL_SETPOINT_LIMIT 
16-bit 
0x954d – 
0x7fff
Read 
only 
0x01F4 
O 
0x0006 
MAX_COOL_SETPOINT_LIMIT 
16-bit 
0x954d – 
0x7fff 
Read 
only 
0x0DAC 
O 
0x0011 
OCCUPIED_COOLING_SETPOINT
16-bit 
Min Cool 
Setpoint Limit 
– Max Cool 
Read / 
Write 
0x0A28 
M