HeathCo LLC WRC6032TX ユーザーズマニュアル

ページ / 6
4
598-1302-00
DRAFT COPY
Motion Sensor Controls
RANGE
ON-TIME
DUALBRITE™
MAX
DUSK TO
DAWN
TEST    1    5
                (MINS)
3
HRS
OFF
MIN
Range Control
D
UAL
B
RITE
ON-TIME Control
Motion Sensor Sensitivity
The detector is most sensitive to motion across its fi eld of view.
Motion
Most Sensitive
Least Sensitive
Motion
Sensor
Sensor
Maximum
Coverage Angle
Maximum Range
Motion Sensor Coverage Area
70 ft. 
(21 m)
8 ft. 
(2.4 m)
180°
Aim Sensor Down 
for Short Coverage
Aim Sensor Higher 
for Long Coverage
Adjusting Motion Sensor Coverage
3.  Adjust RANGE Control. To increase sensitivity, turn the RANGE 
control toward MAX. To decrease sensitivity, turn the RANGE 
control toward MIN. Note: If the RANGE is set too high, false 
triggering may result in some environments.
 
Note: When using test mode to check operation in the day time:
A.  Set the DETECT control switch to DAY/NIGHT and
B.  Set the ON-TIME control to TEST.
4.  Set ON-TIME Control. Determine the amount of time you want 
the connected device to stay on after motion is detected (1 or 
5 minutes). Slide the ON-TIME control to the corresponding 
setting.
IMPORTANT: Avoid Aiming Control At:
•  Objects that change temperature rapidly, such as heating vents, 
fans, and air conditioners. These air sources could cause false 
triggering.
•  Areas where pets or traffi c may trigger the control.
•  Nearby large, light colored objects refl ecting light may trigger the 
shut-off feature. Do not point other lights at the sensor.