38
ZONE INFORMATION
the panel sends only a fault report from the first zone to the receiver.
Note: If CRS ZONE is YES, a valid CRS ZN TIME must be programmed in System
Options for this feature to be enabled.
Cross-zoning is not compatible and cannot be enabled for Fire Verify
zone types.
33.16 Priority
Selecting
YES allows you to provide additional protection for a zone by requiring it
to be in a normal condition before its assigned area can be armed. A priority zone
cannot be bypassed.
A Priority zone not in a normal condition cannot be armed. If a user attempts to
arm the area, the keypad displays the bad zone name followed by
PRIORITY ZONE
and the arming is stopped.
33.17
Traffic Count
This option is displayed for NT or EX type zones. Select
YES to provide reporting
to the receiver of the number of zone trips while in a disarmed state. The number
of trips for each zone set as traffic count are added together and included with
the area closing message and reported to the central station automation system.
Default is NO.
33.18
Zone Audit Days
Enter the number of days (0 to 99) allowed to elapse without the zone being
tripped before a fault message is sent. The message is sent to the receiver(s)
programmed to receive Supervisory/Trouble Reports at 10:00 am following the
expiration of the timer. Each time the zone is tripped, the Zone Audit Days timer
restarts and begins to countdown the number of days programmed. After the
countdown expires, a fault message is sent and the Zone Audit Days timer restarts
and begins to countdown the number of days programmed. Available for all zone
types except fire and fire verify. Enter 0 (zero) to disable this function. Default is 0
(zero).
33.19
Receiver Routing
This option displays if Zone Type is set for Auxiliary 1 or Auxiliary 2.
Press any top row key to select the Receiver Routing for the selected zone.
• Select NORM to send Alarm and Supv/Trbl messages from this zone to receiver 1
or receiver 2 as programmed within the receiver.
• Select 1 to send Alarm and Supv/Trbl messages from this zone to receiver 1 only,
regardless of the programming for that receiver.
• Select 2 to send Alarm and Supv/Trbl messages from this zone to receiver 2 only,
regardless of the programming for that receiver.
• Select BOTH to send Alarm and Supv/Trbl messages from this zone to both
receivers, regardless of the programming for either receiver.
33.20
Zone Number
Enter the zone number you want to program next. Return to section 32.1 and
follow the descriptions of each programming option. If all zones are programmed,
press the ARROW key at the
ZONE NO: – display to continue.
Stop
34.1 Stop
PRIORITY NO YES
TRAFFIC COUNT
NO YES
ZONE AUDIT DAYS:
0 - 0
RECEIVER ROUTING
NORMAL
NORM 1 2 BOTH
ZONE NO: -
00
STOP