5819S Wireless Shock Sensor and Transmitter  –  Installation Instructions
 
 
The 5819S includes an omni-directional, built-in shock sensor, and is designed to protect window and 
door surroundings. Use this Shock Sensor and Transmitter with alarm systems that support Honeywell 
5800 Series wireless devices.
 
 
Typical shock protection area: 
6 - 8 feet / 3 - 4 foot radius (1.8m – 2.44m / 0.91m – 1.23m radius)
The coverage area can vary depending on the mounting surface. 
The device supports three unique zones or “loops”: 
Loop 1:  Normally Open, built-in shock sensor* 
Loop 2:  Normally closed, built in reed switch, used with the included magnet 
Loop 3:  Externally wired, closed-circuit contact loop connected to the Terminal Block 
*Note: This device features the option to enable Loop 1 to report both shock and reed switch  
faults to the panel 
on a single zone (see Enroll and Program section for details). 
 
Open the Sensor 
 
 
 
Install the Battery 
 
 
BATTERY CAUTION:  Risk of fire, 
explosion, and burns.  Do not recharge, 
disassemble, heat above 212°F (100°C), or 
incinerate.  Dispose of used batteries 
properly.  Keep away from children. 
Enroll and Program 
1.  Install the battery and ensure all the DIP Switches are 
OFF (Highest Sensitivity setting).   
2.  Assign an individual zone number to each loop used* and 
assign the zones as 
Input Type = 3 (Supervised RF)
*Note: To set Loop 1 to report both shock and reed switch 
faults on a single zone, enroll Loop 1 (do not enroll Loop 2), 
and set DIP Switch 4 ON 
after enrollment. 
3.  Activate any of the device loops (see loop descriptions 
above) to transmit the device serial number to the control.   
  For Loop 1, trigger the shock sensor by shaking the 
device, or create a shock near the mounted device. 
  For Loop 2, move the magnet close to and away from 
the reed switch to trigger it.  
  For Loop 3, Open and close the contact according to its 
instructions.  
4.  Trigger again to complete enrollment. 
The LED will flash rapidly to indicate the device is 
transmitting to the control.  
Alternatively, enter the device serial number manually 
when prompted for the information. 
DIP Switch Settings 
After enrollment, test and adjust the device sensitivity 
until the desired setting is achieved. (Refer to the 
Test section.)
 
DIP SWITCH  SETTING 
 
Most Sensitive 
(use this setting for 
enrollment)
 
 
High Sensitivity 
 
Medium Sensitivity 
 
Low Sensitivity 
 
 
*Set ON - Loop 1 reports both shock 
and reed switch faults 
on a single 
zone 
  Set OFF – Loop 1 reports shock 
only 
 
 
Do NOT Remove the PC Board from the back case 