5819S Wireless Shock Sensor and Transmitter – Installation Instructions
The 5819S includes an omni-directional, built-in shock sensor, and is designed to protect window and
door surroundings. Use this Shock Sensor and Transmitter with alarm systems that support Honeywell
5800 Series wireless devices.
Typical shock protection area:
6 - 8 feet / 3 - 4 foot radius (1.8m – 2.44m / 0.91m – 1.23m radius)
;
The coverage area can vary depending on the mounting surface.
The device supports three unique zones or “loops”:
The device supports three unique zones or “loops”:
Loop 1: Normally Open, built-in shock sensor*
Loop 2: Normally closed, built in reed switch, used with the included magnet
Loop 3: Externally wired, closed-circuit contact loop connected to the Terminal Block
*Note: This device features the option to enable Loop 1 to report both shock and reed switch
*Note: This device features the option to enable Loop 1 to report both shock and reed switch
faults to the panel
on a single zone (see Enroll and Program section for details).
Open the Sensor
Install the Battery
BATTERY CAUTION: Risk of fire,
explosion, and burns. Do not recharge,
disassemble, heat above 212°F (100°C), or
incinerate. Dispose of used batteries
properly. Keep away from children.
Enroll and Program
1. Install the battery and ensure all the DIP Switches are
OFF (Highest Sensitivity setting).
2. Assign an individual zone number to each loop used* and
assign the zones as
Input Type = 3 (Supervised RF).
*Note: To set Loop 1 to report both shock and reed switch
faults on a single zone, enroll Loop 1 (do not enroll Loop 2),
and set DIP Switch 4 ON
after enrollment.
3. Activate any of the device loops (see loop descriptions
above) to transmit the device serial number to the control.
•
•
For Loop 1, trigger the shock sensor by shaking the
device, or create a shock near the mounted device.
•
For Loop 2, move the magnet close to and away from
the reed switch to trigger it.
•
For Loop 3, Open and close the contact according to its
instructions.
4. Trigger again to complete enrollment.
The LED will flash rapidly to indicate the device is
transmitting to the control.
Alternatively, enter the device serial number manually
Alternatively, enter the device serial number manually
when prompted for the information.
DIP Switch Settings
After enrollment, test and adjust the device sensitivity
until the desired setting is achieved. (Refer to the
Test section.)
DIP SWITCH SETTING
Most Sensitive
(use this setting for
enrollment)
High Sensitivity
Medium Sensitivity
Low Sensitivity
*Set ON - Loop 1 reports both shock
and reed switch faults
on a single
zone
Set OFF – Loop 1 reports shock
only