9.3.1  Installation with an Internal POTS Splitter
TIP
RING
3
4
4
5
DSL TIP
DSL RING
PHONE (RJ11)
LINE
RX+
RX-
TX+
TX-
10BaseT
TO CPE
]
1
2
3
6
ATU-R
S-0111-A
Figure 6.  Installation Diagram with an Internal POTS Splitter
Use the following procedure:
 
1.  Connect the power transformer to the back of the unit and then plug into the wall
power receptacle.
 
2.  Connect either an 8-pin module cable or a standard 6-pin telephone cable from the
LINE connector on back of the unit to the network jack.
 
3.  Connect the proper Ethernet cable from the 10BaseT connector to the interface on
the CPE equipment (for example, the PC NIC card).
 
4.  Connect the phone to connector phone connection on the back of the unit.
 
5.  Power the unit ON.
 
6.  By observing the 
READY
 LED, check the unit to ensure that the power self-test has
successfully completed, and that the unit is synchronized with the access line
module.  It may take from 50 to 70 seconds for the unit to achieve line synchronization
with the central office ADSL unit.  The 
READY
 LED illuminates to a steady green to
show that the unit is synchronized.
 
7.  Verify the connection to the CPE by observing the 
LINK
 and 
ACTIVITY
 LEDs on the
front of the unit.