SuperVision® System Manual
CAP Rate-Adaptive Ethernet DSL Remote Unit
A90-36R210W00
Part # 030-1010xx
A90
Rev. 
P2
, 07/01/98
1998, Westell, Inc
.
Release 1.2
Printed in the USA
10BT-R.DOC
14
9.3.2  Installation without an Internal POTS Splitter
4
5
DSL TIP
DSL RING
LINE
RX+
RX-
TX+
TX-
10BaseT
TO CPE
]
1
2
3
6
ATU-R
S-0112-A
Figure 7.  Installation Diagram without a POTS Splitter
Use the following procedure:
 
1.  Connect the power transformer to the back of the unit and then plug into the wall power
receptacle.
 
2.  Connect the 8-pin module cable or a standard 6-pin telephone cable from the 
LINE
connector on back of the unit to a POTS splitter (refer to POTS splitter data sheet for
instructions) or to the network jack if POTS service is not provided.
 
3.  Connect the proper Ethernet cable from the 10BaseT connector on the back of the unit to
the interface on the CPE equipment (for example, the PC NIC card).
 
4.  Power the unit ON.
 
5.  By observing the 
READY
 LED, check the unit to ensure that the power self-test has
successfully completed, and that the unit is synchronized with the access line module.  It
may take from 50 to 70 seconds for the unit to achieve line synchronization with the
central office ADSL unit.  The 
READY
 LED illuminates to a steady green to show that the
unit is synchronized.
 
6.  Verify the connection to the CPE by observing the 
LINK
 and 
ACTIVITY
 LEDs on the front of
the unit.