4. 
Charging the Transmitter Batteries with the Battery Charger 
4.1  Functional Overview 
• 
Universally usable due to switching power supply technology [100-240 VAC] and primary-side 
exchangeable plug system, 
• 
Test phase at start of charging in order to ascertain the number of cells and to detect and indicate 
faulty batteries, 
• 
Short-circuit detection and electronic reversed polarity protection, 
• 
Monitoring of the charge condition during the entire charging time with a microcontroller, 
• 
Predischarging of the battery by button pressing possible; thereafter automatic switchover to 
charging, 
• 
Status display by LEDs, 
• 
Automatic switchover to pulse trickle charging. 
• 
Charging only in the temperature range +5 °C to +45 °C . 
 
 
 
4.2  Indication on the Charger 
 
 
POWER UNIT UCC 11 0
UCC 11 0
N10467
Q04574
BT 097 -00303
C        US
OPEN
D
is
c
h
a
rg
e
R
e
a
d
y
C
h
a
rg
e
P
o
w
e
r
PRESS
[1]
[2]
[3] [4] [5]
+
-
Positive inside
E U
USA
UK
 
 
 
 
 
Indications 
Description 
Red ‘Power’ LED [1]: 
Permanent light signals that the charger is ready for operation. 
Lights up as soon as the charger is connected to the mains 
supply. 
Red ‘Charge’ LED [2]: 
Permanent light signals the charging after the contacting of the 
battery. 
Green ‘Ready’ LED [3]: 
Permanent light signals that the battery is charged. The green 
LED switches to blinking mode after approximately 2 minutes 
= pulse trickle charge. 
Yellow ‘Discharge’ LED [4]: 
Permanent light signals (after pressing of the yellow discharge 
button), the discharging. Simultaneously, the ‘Ready’ LED 
blinks for approximately 1 minute to signal the test phase. 
Discharge button [5]: 
Pressing the discharge button [for approx. 2 s] starts the 
discharging of the battery.