Laird Controls North America Inc. EXC9158A ユーザーズマニュアル

ページ / 25
 
 
 
Edition 04/2007 US, Version A001, Excalibur, Subject to Technical Changes 
                                                            Page: 11 
 
 
3.2.3 Relay Status Indication 
Each relay has an LED on the pcb for display of the relay status [only visible with removed housing 
cover].   
 
 
3.2.4 Power und Status Indication 
The receiver has 5 externally visible LEDs that display the current system status. 
 
             
 
 
LED 
Description 
1: Power On 
Lights orange: 
as soon as the receiver has voltage  
2: 
Without function 
3: RF Reception 
Lights green:   
if valid data from the transmitter is received and both K0 relays are 
activated. 
Lights orange:  
if valid data from the transmitter is received and the K0 relays are 
deactivated. 
Lights red:  
if data from another transmitter [with invalid address] is received. 
OFF,  
if no transmitter is identified. 
4: Command 
Lights green:   
if commands are received [normal condition] 
5: Fault indication 
Blinks red: 
This LED flashes a fault code if the receiver detects a fault at any time. 
 
 
 
Note! 
A further LED [6], which displays the status of the second processor, is located on the 
processor pcb.  
The LED [6] blinks orange if the receiver does not detect a transmitter, and green if valid 
telegrams are received. If the 2nd processor detects a fault, it will signal this by 
blinking in red, see appendix for blink sequences.