Status Monitor Program  
2-4 
 
602-13729-01 Rev B 
 
Expedio Digital Electronic News Gathering Radio
 
Decoder 
Indicates the operating mode of the unit: 
GREEN = decoder 
RED = encoder 
NO COLOR (background) = Unknown  
PVR 
Indicates the PVR status: 
GREEN = Valid 
RED = Invalid 
NO COLOR (background) = Unknown, only occurs before status is 
obtained or during reset. 
CPU Version 
The version of firmware.  
FPGA Version 
The version number of the unit’s operating system. 
Updates to the CPU Version or the FPGA Version can only be performed under the guidance of 
Moseley Technical Support.  
Read from Board returns status information (excluding PVR) without starting Status Check.  
2.3.3 Error 
Statistics 
The lower portion of the Status area displays Error Statistics. This is live data that the system 
updates as changes occur on the unit. The represented values include: 
• 
Time 
Gives the elapsed time since Status Checking started. 
• 
TPS 
GREEN = Valid 
RED = Invalid 
NO COLOR (background) = Unknown 
• 
Total TPS 
Number of invalid TPS checks since Status Checking started. 
• 
RS Errors 
 
• 
BER 
 
• 
Signal Strength   
• 
MER 
 
The Reset Totals button returns a field values to zero. The system then updates the fields with 